High Heat Density

High heat density system delivers data center cooling for more than 30 kW per rack. Liebert XD offers floor-mount, rack-mount and ceiling-mount configurations. Utilizes pumped refrigerant, which is ideal for use around electronic equipment. Enhances the hot aisle / cold aisle approach to cooling. High density solutions are configured in 45 ton (160 kW) building blocks with spot cooling modules that range in size from 2.5 to 8 ton (9 to 30 kW).
Common Framework Liebert XDO, XD Overhead Cooling Module, 17.2-20kW

Liebert XDO, XD Overhead Cooling Module, 17.2-20kW

Overhead cooling module that mounts directly above the cold aisle, requiring no floorspace. It draws in hot air from the hot aisle, then discharges cool air into the cold aisle where the equipment air inlets are located.

Common Framework Liebert XDH, 22-30kW​​

Liebert XDH, 22-30kW​​

In-the-row cooling module placed directly in line with the rack enclosures, and requires very little floorspace. Air from the hot aisle is drawn in through the rear of the unit, cooled, and then discharged horizontally through the front of the unit into the cold aisle.

Common Framework Liebert XDV, XD Racktop Cooling Module, 8.8-10kW

Liebert XDV, XD Racktop Cooling Module, 8.8-10kW

Rack cooling module that mounts vertically on or above the IT rack enclosure, requiring no floorspace. It draws hot air from inside the cabinet or from the hot aisle. It then cools the air and discharges it down to the cold aisle.

Common Framework Liebert XD Pumping and Chiller Units, 130-160kW

Liebert XD Pumping and Chiller Units, 130-160kW

The indoor Liebert XD Pumping and Chiller Units include the Liebert XDP and the Liebert XDC units. These refrigerant-based systems support Liebert XD System spot/zone data center cooling modules, including the Liebert XDO, Liebert XDV, Liebert XDH, and Liebert XD CoolFrame units. The Liebert XDP is used between the cooling units and an associated heat rejection system, while the Liebert XDC is used between the cooling units and a chilled water system.

Common Framework Liebert XD Refrigerant-Based Cooling Modules

Liebert XD Refrigerant-Based Cooling Modules

Liebert XD refrigerant-based cooling modules deliver high-density cooling with highly flexible configurations for floor-mount, rack-mount and ceiling-mount applications.

Common Framework Liebert XDA, Air Flow Enhancer, 1000CFM

Liebert XDA, Air Flow Enhancer, 1000CFM

The Liebert XDA rack fan unit optimizes data center cooling by increasing air flow through densely populated enclosures, past congested cabling; removing hot spots within the enclosure that can threaten the uptime of your critical systems.

Common Framework Liebert® DCD Water Based Cooling Modules up to 50 kW with Liebert® DCP 200 kW Pumping Unit

Liebert® DCD Water Based Cooling Modules up to 50 kW with Liebert® DCP 200 kW Pumping Unit

The Liebert® DCW chilled water-based cooling family was designed specifically for high heat density applications where the challenges of reducing energy consumption and increasing processing capabilities are the top priority for data center managers. By delivering cooling directly at the source, the DCD Rear Door Heat Exchanger provides a room-neutral environment, while the DCP Coolant Pumping Unit regulates the chilled water and ensures optimal cooling capacity for mission critical equipment.

Common Framework Liebert® XDU Coolant Distribution Units

Liebert® XDU Coolant Distribution Units

Designed to support liquid cooling within high density environments, the Liebert® XDU Coolant Distribution Units are suitable for chip & rear door cooling applications that offer easy, cost-effective deployment in any data center. The Liebert XDU family offers systems that operate with/without facility water, allowing you to tap into the benefits of liquid-cooled servers to more efficiently support higher rack densities without incurring the costs of major infrastructure changes.